The first hazard is that the primary and secondary windings are close together, which creates the potential for a primary to secondary short in the event of insulation failure. In addition, there is a possibility that the transformer will explode because of the hermetically sealed tank of flammable oil.

There are several steps that line workers can take in order to prevent injuries from distribution transformers. First and foremost, line workers should wear the following protective equipment: hard hats, rubber gloves, safety glasses, and fire retardant clothing. A line worker should always connect the neutral first before connecting the transformer and remove it last before disconnecting the transformer. To avoid the possibility of backfeed, there should not be any paralleling of transformers across any point that could be used to isolate a line section.

Stuck Writing Your "Distribution Transformers Transformer Is A" Term Paper?

A line worker should always wear rubber gloves if working on the secondary coil of a faulty transformer. Transformers should be de-energized before servicing or repairing. Finally, before a transformer is re-fused, a line worker should thoroughly inspect the transformer and test it with an approved instrument. When refusing transformers, line workers should also disconnect the customer's load, and use an extendable live line tool. In fact, it is recommended that line workers maintain a distance of at least 10 feet from the transformer prior to re-fusing. Prior to refusing, transformers should be tested with a smaller test fuse. Finally, transformers should be replaced rather than re-fused if the pressure relief valve has operated or an auxiliary current limiting fuse has blown.

Works.....

Show More ⇣


     Open the full completed essay and source list


OR

     Order a one-of-a-kind custom essay on this topic


sample essay writing service

Cite This Resource:

Latest APA Format (6th edition)

Copy Reference
"Distribution Transformers Transformer Is A" (2005, March 21) Retrieved July 4, 2025, from
https://www.aceyourpaper.com/essays/distribution-transformers-transformer-63473

Latest MLA Format (8th edition)

Copy Reference
"Distribution Transformers Transformer Is A" 21 March 2005. Web.4 July. 2025. <
https://www.aceyourpaper.com/essays/distribution-transformers-transformer-63473>

Latest Chicago Format (16th edition)

Copy Reference
"Distribution Transformers Transformer Is A", 21 March 2005, Accessed.4 July. 2025,
https://www.aceyourpaper.com/essays/distribution-transformers-transformer-63473